Top Condensing Boilers
Supplying Demand CP115 SPCP115 HVAC/R Condensate Pump with Alarm 1/10HP 115VAC
- High quality pump designed to remove condensate from AC systems, condensing furnaces and boilers, ice machines, drinking fountains, and coolers. These pumps incorporate an audible alarm, and an overflow switch that can be used to shut down the system..
- Applications include HVACR, ice machines, drinking fountains, and coolers..
- 22 feet of standard lift at 10 GPH | Independent NC safety switch & motor switch | Suitable for acidic condensate | 1/4 inch quick-connect terminals | 3 terminals are provided for easy connection | Independent NO audible alarm switch rated at 80 dB.
- Specially designed leak-free motor and safety float | 3/8 inch rubber ball check valve | Vibration absorbing feet | Metal side mount tabs, 11-1/2 inches on center | 3 inlet holes | 6 foot power cord included.
- Alarm Sound Level: 80 dB | Maximum Temperature: 110° F | Tank Capacity: 1/2 gallon | Discharge: 3/8 inch | Barb. Frequency: 60 Hz | Motor Overload Protector: Yes | Amperage: 1.45 A | Watts: 80 W | UL Listed: Yes | Motor Horsepower: 1/10 HP | Voltage: 115 VAC | Dimensions: 5 inches wide x 11-1/4 inches long x 7-1/4 inches tall.
Check StockLittle Giant VCMX-20ULS-C 115 Volt, 1/30 HP, 84 GPH, Automatic Condensate Removal Pump, 6-Ft. Power Cord, Safety Switch, Anti-Sweat Sleeve, Blue, 554542
- APPLICATIONS: ideal for collecting, detecting, and automatic removal of condensate from air conditioning equipment, dehumidifiers, high efficiency furnaces, condensing boilers, and other equipment.
- COMES EQUIPPED WITH: external test/run level.
- galvanized steel "quick install" wall mount bracket.
- INCLUDES OVERFLOW DETECTION SWITCH: dual function NO and NC operation.
- shuts off equipment or can be attached to audible or visual alarm or security system.
- AUTOMATIC OPERATION: vertical centrifugal pump design activates when condensate reaches 2.2 inches.
- shuts off when condensate falls to 1.6 inches.
- SPECIFICATIONS: 1/30 HP, 115 Volts, 60 Hz., 1.5 Amps, 93 Watts, 3/8-inch discharge, check valve included, 84 GPH at 1-ft. lift, 21 ft. shut-off, maximum 9.1 PSI.
Check StockLittle Giant VCMX-20ULST 115 Volt, 1/30 HP, 84 GPH Automatic Condensate Removal Pump, 6-Ft. Power Cord, Safety Switch, 20-ft. 3/8-inch Tubing, Blue, 554550
- APPLICATIONS: ideal for collecting, detecting, and automatic removal of condensate from air conditioning equipment, dehumidifiers, high efficiency furnaces, condensing boilers, and other equipment.
- galvanized steel "quick install" wall mount bracket.
- rubber feet for vibration noise dampening.
- INCLUDES OVERFLOW DETECTION SWITCH: dual function NO and NC operation.
- shuts off equipment or can be attached to audible or visual alarm or security system.
- AUTOMATIC OPERATION: vertical centrifugal pump design activates when condensate reaches 2.2 inches.
- shuts off when condensate falls to 1.6 inches.
- SPECIFICATIONS: 1/30 HP, 115 Volts, 60 Hz., 1.5 Amps, 93 Watts, 3/8-inch discharge, check valve included, 84 GPH at 1-ft. lift, 21 ft. shut-off, maximum 9.1 PSI.
Check StockLittle Giant EC-400, 2.5 GPH In-Pan Condensate Removal Pump (115V)
- ...tomatic Condensate Pump features safety switch, 1/2-gallon ABS plastic tank, and 6 ft. power cord.
- 1/30 HP pumps 80 gallons of water per hour.
- Product 1: AUTOMATIC HVAC PUMP: Ideal for collecting, detecting, and automatic removal of condensate from air conditioning equipment, dehumidifiers, high efficiency furnaces, condensing boilers, and other equipment where automatic drain pump is required.
- Product 1: STAINLESS STEEL MOTOR SHAFT: Vertical-type pump features stainless steel motor shaft and galvanized steel tank cover.
- Thermally protected motor is UL and CSA listed.
- Includes two 1-1/8” diameter inlet openings.
- Product 1: PUMP WITH SAFETY SWITCH: Includes safety switch which can be connected to shut down the air conditioner condenser or wired to an alarm to warn of possible tank overflow.
- Discharge is a 1/4" FNPT or 3/8" O.D. barbed tubing adapter.
- Product 2: SimpleAir’s Clean Flow Tabs are a simple method to maintain free-flowing drain lines associated with all HVAC systems.
- Product 2: Unique tablets are time released when water activated.
- Product 2: Tabs prevent common growth in drain lines that could lead to clogging of drain lines and overflow.
- Product 2: Each tablet lasts up to 2 months.
Check StockAquastrong 1/38HP 85 GPH HAVC Condensate Pump, 115V/230V, Automatic Safety Switch, AC Condensate Removal for Air Conditioner, Furnace, Dehumidifier, 3.3' Power Cord
- ...t when the water level reaches 2.28'' and auto stop by 1.26''. 3.3ft UL power cord with 3-prong plug ensures safety and convenience. It is necessary to clean the pump reservoir, float and filter basket at least every six months to prevent clogging.
- Worry-free: Strong condensation pump for furnaces, air conditioners, condensing boilers, dehumidifiers and commercial ice makers. This product comes with a two-year warranty. Aquastrong customer service provides professional installation and maintenance supports.
Check StockAquastrong Mini Split HAVC Condensate Pump, 9.6 GPH, 115V/230V, Automatic Safety Switch, AC Condensate Removal for Air Conditioner, Furnace, Dehumidifier, 3.3' Power Cord
- ...with 3-prong plug ensures safety and convenience. It is necessary to clean the reservoir, float and filter at least every six months to prevent clogging. Please make sure to install the reservoir vertically with the magnet facing upward.
- Worry-free: Small powerful condensate pump for air conditioners, dehumidifiers, condensing boilers and furnaces. This product comes with a two-year warranty. Aquastrong customer service provides professional installation and maintenance supports.
Check StockNoritz NC-1
- Designed to neutralize all acidic condensate produced by condensing water heater models.
Check StockBreville BES980XL Oracle Espresso Machine, Brushed Stainless Steel
- Automatically grinds, doses & tamps the required amount of coffee for mess free, barista-quality espresso.
- Programmable hands-free milk texturing with automatic purge.Water tank capacity-84 ounce.
- Dual stainless steel boilers & dual Italian pumps with PID.
- Boilers can be descaled by user. Power:1800 Watts.
- One Touch Americano delivers water directly into the cup after extraction.
- Programmable shot temperature from 190 Degree-205 Degree. Displays in either Degree F or Degree C.Over Pressure Valve: This commercial feature limits the 15 bar Italian pump pressure throughout the extraction, preventing bitter flavours in the shot.
Check StockNoritz SV-CK-3 3' SV Conversion Kit (required for DV to SV conversion)
- Converts condensing (DV) direct vent models to atmospheric design for EZ98 and 111DV models..
- Built-in bird/bug screen to protect blower motor.
- Converts condensing (DV) direct vent models to atmospheric design. Will consume make up air from available environment such as vented attic space..
- Builtin bird/bug screen to protect blower motor.
- PVC glue on install for ease of installation.
Check StockTripod Clamp Mount, Lab Stand Holder Cross Clip, for Experiment Laboratory
- ADJUSTABLE TONG OPENING: Because of flexible tong opening, the condensing tube clamp can be used in different specifications of the lab instrument..
- STRONG CLAMPING FORCE: The four-claw lab clamp features strong clamping force, which makes sure that the experiment supplies held by the clamp will not fall..
- FLEXIBLE HANDLE: The handle can rotate 360 degree, which allows for pouring the chemical solutions easily..
- FOUR CLAW DESIGN: The beaker clamp adopts four-claw design, which improves its clamping force..
- APPLICATION: The condensing tube clamp is suitable for clamping various lab supplies such as condenser pipe, flask, etc..
Check StockOriginal Dental Flexi-Thin Composite Filling Instruments for Anterior Non-Stick Set of 5 by Wise Instruments
- For small pit and fissures, tunnel preps or minor tooth defects on lower anteriors..
- Flexible, reversed, flared paddle design for shaping and placement of full veneer bonding..
- Mini Micro for extremely small pits and fissures..
- Used for small pits and fissures, Placement and condensing with limited access..
- For final placement of Class I & II restorations. The ball end for condensing and shaping in Class I & II and lingual surfaces of anterior teeth..
Check StockXuee 1/2\3/4\ 1\Inner top Water Inlet Automatic Float Valve Water Level Control Valve, Used for Solar Water Tank Tower Pool (3/4\)
- Easy to install: small size, estimated flow rate up to 40 psi 3 gallons per minute, 60 psi 5 gallons per minute.
- The valve replaces the traditional float valve, no electricity, easy to use, long life, low failure rate, and save water resources..
- Widely used in: water tanks, water towers, swimming pools, solar energy, toilets, hot water boilers, animal drinking water, air cooling, humidifiers, civil buildings, cooling towers, hot water boilers, steamers, water tanks, water towers, toilets.
- Made by a Chinese manufacturer. Made of high-quality materials and accepts all Amazon FBA customer service policies.
Check Stock