Top Electrical Contactors
NR2-93 Thermal Overload Electric Overload Relay Motor Protection Thermal Overload 50-60hz (37-50A)
- 10.0 - 16.0 Amp, IEC, Overload Relay, Type: Thermal Bi-Metallic. Trip Class 10. Selectable Manual or Automatic Reset. For use with XT Series, Frame D Contactors..
Check StockPackard - DP301202 C230B 2 Pole 30 Amp Contactor, 120 Voltage Coil
- Compatible with: C230B/ TJT30A120V2P/17325/PC230A/H230A/90-244.
- In accordance with U. L. bulletin no. 508 “industrial control equipment”.
- Contactors meet specifications for devices up to 600 VAC.
- Coils have class b insulation. Resistive Amps : 40.
- Includes lug, spade terminals, and covers.
Check Stock20 in. x 20 in. x 1 in. Basic Household Pleated Air Filter (3-Pack)
- This is a Brand New Upgraded 1 Pole 30 Amp Condenser Contactor.
- This contactor is rated for 30 amps, meaning it is an upgrade for old 25 amp contactors.
- The coil is rated for 24 volts- It also has a sealed contact!.
- This contactor will work with 99% of residential units!.
Check StockLennox - 40 Amp 1 Pole 24v Coil Replacement Contactor C140A
- 40 FLA Amp Rating - 1 Pole - 24 Volt Coil. Replaces Most 2 Pole Contactors Rated at 20 Amps, 25 Amps, 30 Amps, 35 Amps, or 40 Amps on Air Conditioners....
- Can be used for virtually all single pole ac contactor replacements Carrier-Bryant-Payne-Goodman-Amana-Janitrol-Rheem Ruud Weatherking-Lennox,....
- Base assembly is made from high performance Bulk (Dough) molding compounds.
Check Stock115/230VAC Pulling Electric Winch with 11.0 fpm and 2000 lb. 1st Layer Load Capacity
- All brass (no corrosion) series wound that is double sealed.
- Sealed waterproof 600 amp contactors and steel contactor cover for added protection.
- Double sealed drum (gearbox/motor) and sealed 3 stage planetary gears as well as aluminum fairleads and integrated wireless remote.
- Fully sealed to Ip68 standard and tie bars reinforced with steel body.
Check StockTrane • 40 Amp 1 Pole 24v Coil Packard Replacement Contactor C140A
- 200K cycles UL testing approval for Dp contactor.
- Replace SIEMENS 45 series dp contactor 1 pole 40FLA 24V coil.
- UL,CUL CSA, SEV S+, CE Approved AC contactor.All our DP contactors series meet the ARI Standard 780/790-1997 and UL508 standard.
- Replacement parts number: 8910DP41V14, 3100-15Q19, C25ANF140T, 45GG10AJA,HCCY1XQ04GG, C140A, DP40241..
Check StockNEW TeSys LRD thermal overload relays LR-D16 LRD16 9-13A Class 10A
- Class 10 Ambient Compensated Overload with Phase Loss Protection..
- New Aftermarket Replacement for Telemecanique Overload Relay including a 1 year warranty..
- "12-18A Adjustable Overload Mounts to NC1- D12, D18, D25 or D32 Contactor".
- Series LR overload relays are intended and UL recognized for use with US Breaker NC1D contactors..
- Telemecanique parts are provided to assist selection. Select products according to each applicaion..
Check StockMGN9H Carriage Block for MGN9 Linear Sliding Rail Guide
- Multipurpose : Can be installed in all types of terminal boxes, distribution boxes, control cabinets, switchgear, complete sets of equipment, machinery and equipment..
- Versatility : Perfect for any type of electronic component or device, such as relays, contactors, breakers and more.
- Easy to install : Practical design with screws for easy installation.
- Length : 100mm/ 4"(-1%) (For easy installation).
- Package Contents: 3pcs x DIN rails + 6pcs x screws.
Check StockMcdonnell & Miller Flow Switch, 1 in SPDT FS4-3
- Working Temperature: -10 to 50 Degrees Celsius.
- Tip: The max switching current of the contact is 0.5A. Generally, it should be used together with small relay. Excessive current will burn the contact. Cannot directly control AC contactors, solenoid valves, alarms, pumps, and various lights..
- What is in the package: 2pcs M16 Water Level Sensor.
Check StockANTOBLE PC140A C140A Contactor Single One 1 Pole 40 Amps 24 Volts A/C Air Conditioner
- 40 FLA Amp Rating - 1 Pole - 24 Volt Coil. Replaces Most 2 Pole Contactors Rated at 20 Amps, 25 Amps, 30 Amps, 35 Amps, or 40 Amps on Air Conditioners....
- Enclosed Contacts and Encapsulated 24 Volt Coil.
- Heavy Lug Terminals and Push-Ons for High Voltage Connections.
- Can be used for virtually all single pole ac contactor replacements Carrier-Bryant-Payne-Goodman-Amana-Janitrol-Rheem Ruud Weatherking-Lennox,....
Check StockLennox • 30 Amp 1 Pole 24v Coil Fasco Replacement Contactor H130A
- 30 Amp , 1 Pole with Shunt , Coil Voltage: 24v.
- Definite Purpose Contactor , Universal Component..
- Fasco contactors meet specifications for devices up to 600 VAC in accordance with UL Bulletin No. 508, Industrial Control Equipment..
- Screws and quick connect terminals , Coils have Class B insulation.
- Replaces / Supersedes: FASCO H130 Packard C130 C130A MARS JARD Packard 3100-15Q228 York 024-27531-000 91311 3100Y15Q200 3100-15Q128 P282-0311 HN51KB024 HN51KC024 3100-15Q128 HN51KB024 425066 621661 ICP 1173689 P282-0311 CTR1143 CTR01143 CTR-1143 and many other brands at specifications shown..
Check StockH130A Fasco Replaces Carrier HN51CB025 / HN51KC024 / HN51KB024-30 Amp 1 Pole 24v Coil Contactor
- 30 Amp , 1 Pole with Shunt , Coil Voltage: 24v.
- Definite Purpose Contactor , Universal Component..
- Fasco contactors meet specifications for devices up to 600 VAC in accordance with UL Bulletin No. 508, Industrial Control Equipment..
- Screws and quick connect terminals , Coils have Class B insulation.
- Replaces / Supersedes: FASCO H130 Packard C130 C130A MARS JARD Packard 3100-15Q228 York 024-27531-000 91311 3100Y15Q200 3100-15Q128 P282-0311....
Check Stock