Top Real time Thermocouple

Honeywell International Q340A1074 Thermocouple

  • commercial gas range stove universal thermocouple 900mm long.
  • It is a type of temperature sensor need to work with gas safety valve.
  • End Connection nuts on thermocouple : M9*1.
  • Voltage: 003e20mV Openning valve time: less than 10s.
Check Stock

K Type Thermocouple Temperature Thermocouple Sensor Temperature Detector Temperature Gauge with M4 Thread for 3D Printer Temperature Sensor

  • Type K (chromel–alumel) is the most common general-purpose thermocouple with a sensitivity of approximately 41 µV/°C.[10] It is inexpensive, and a wide variety of probes are available in its −200 °C to +1350 °C (−330 °F to +2460 °F) range. Type K was specified at a time when metallurgy was less advanced than it is today, and consequently characteristics may vary considerably between samples. One of the constituent metals, nickel, is magnetic.
  • a characteristic of thermocouples made with magnetic.
  • They operate very well in oxidizing atmospheres. If, however, a mostly reducing atmosphere (such as hydrogen with a small amount of oxygen) comes into contact with the wires, the chromium in the chromel alloy oxidizes. This reduces the emf output, and the thermocouple reads low. This phenomenon is known as green rot, due to the color of the affected alloy. Although not always distinctively green, the chromel wire will develop a mottled silvery skin and become magnetic. An easy way to check for t.
  • Hydrogen in the atmosphere is the usual cause of green rot. At high temperatures, it can diffuse through solid metals or an intact metal thermowell. Even a sheath of magnesium oxide insulating the thermocouple will not keep the hydrogen out..
Check Stock

Thermco ACC310DLSDIG Laboratory Long Stem Digital Thermometer, 12\ Stem Length, -50 to 300°C Range, +/-1.0°C Accuracy

  • High Temperature K-type Thermocouple Thermometer Set with Stainless Steel Probe.
  • K-type thermocouple wire with Standard Accuracy: +/- 2.2 °C or +/- .75%.
  • 5 ft (155 cm) long thermocouple cable with braided stainless steel cover, mini thermocouple plug made from chromel / alumel.
  • Temperature measurement range: -328 to 932 °F (-200 to 500 °C), short term 1472 °F (800 °C).
  • Grounded K-type Thermocouple junction for fast measurements, 1x 9V battery included.
Check Stock

3\ Outside Air Kit for Pellet Stoves with 3\ Air Intake Pipe Including Harman Stoves 3\ X 10'

  • QuadraFire Thermocouple 800, 1000, 1100i, 1200, 1200i Pellet Stoves 812-0210.
  • Top Quality Aftermarket Replacement Part.
  • The Thermocouple is the device that monitors the fire after start-up. Once it reaches temp the thermocouple allows the stove to start feeding on it's own in normal operation mode. If your stove goes out after the initial start-up cycle, more than likely the thermocouple needs to be replaced..
  • Designed Specifically for the above mentioned models.
Check Stock

Emerson H06F 36 Universal Junction Block Thermocouple 36 inch

  • 36 inch junction block thermocouple with energy cut-off.
  • Stainless steel element construction for prolonged thermocouple life.
  • Standard coaxial thermocouple 11/32 inch double lead thread.
  • Universal adapter fittings included with each kit for replacing thermocouple in most types of pilot burners.
  • Works for both LP and natural gas applications.
Check Stock

HUATO S220-T8 Eight Channel Thermocouple Data Logger with External Power Supply and 3 Points NIST Traceable Certificate, Measuring Range -200 to 1800°C

  • 8 Channel Data Logger with Large LCD Temperature Reading Display.
  • Support Thermocouple Type K, J, E, T, N, S, R, B Measuring Range from -200 to 1800°C.
  • Input Isolation Protection Between Each Channel & High Accuracy Reading Across.
  • Recording Up to 86,000 Data Points Per Channel and Real Time Monitoring Functionality.
Check Stock

Multi Channels Digital Industrial Thermometer Temperature Data Logger (AT4716)

  • Test range: -200 ° C ~ 1800 ° C Resolution: 0.1 ° C Accuracy: 0.2% ± 1.
  • AT4808 handheld multi-channel temperature meter adopts high-performance ARM micro processor, can collect multi-channel temperature data simultaneously and response quickly..
  • AT4808 has the function of checking broken thermocouple, high/low beep function and communication transmission. 128 channels temperature data can be extended, compatible with various temperature sensors. Equipped with Mini-USB (virtual series port) interface to realize data acquisition, analysis and print through the standard computer software. Support USD disk storage, real-time sampling data storage. The users can adjust data for each channel independently..
Check Stock

Amprobe TMD-56 Multi-Logging Digital Thermometer, 0.05% Basic Accuracy

  • Portable, dual-input thermometer for reading temperatures from two sources simultaneously, and USB data transfer, and is used in quality control and HVAC, electrical, industrial, and automotive maintenance.
  • Accepts K-, J-, T-, E-, R-, S-, and N-type thermocouples.
  • Dual-scale temperature readings range from -328 to 2,498 degrees F (-200 to 1,370 degrees C).
  • Dual-input thermocouples for superheat and subcool applications, and cut-out and cut-in temperature measurements, and offset mode compensates for thermocouple error.
  • USB port exports data, and built-in memory saves up to 16 sets of data with 16,000 data points, and datalogging saves up to 256 samples with real-time data.
Check Stock

Amprobe TMD-50 Thermocouple Thermometer K-type

  • Portable, dual-input thermometer for reading temperatures from two sources simultaneously, and is used in quality control and HVAC, electrical, industrial, and automotive maintenance.
  • Dual-scale temperature readings range from -328 to 2,498 degrees F (-200 to 1,370 degrees C).
  • Dual-input thermocouples for superheat and subcool applications, and cut-out and cut-in temperature measurements, and offset mode compensates for thermocouple error.
  • Backlit LCD screen with a data hold feature to save temperature readings for later viewing, maximum and minimum temperature with elapsed time, average and relative temperature calculations, and low battery indicator.
Check Stock

GBC Document Camera, Discovery 3000 (DCV10004)

  • pyrometer Temperature range: -50°C to 1300°C ( -58°F to 2372°F) and Overload display alert when input exceeds measurement range pyrometer. Thermocouple Temperature range: -50°C to 1000°C ( -58°F to 1832°F).
  • Designed for use with K-type thermocouples and Selection between Celsius and Fahrenheit.
  • Decimal or round number display selectable (decimal range is -58.0F to999.9F and round number range is -58F to 2372F).
  • Includes 2 Thermocouples ( One 3" K type temperature probe (-58 – 752 °F) and one Kiln Heavy duty K type Thermocouple ( -58°F to 1832°F) and Digital Pyrometer, 9V battery and Manual.
  • Thermocouple Measurement range: 32 - 1832 °F (0 - 1000 °C) Thermocouple Type: K Type Cable length : 3 ft Sensing tip length: 6" (150mm) Stainless Steel Sensing tip diameter: 0.19" (5mm) Thread width : 5/16" (M8) Internal Insulation: Fiber Glass External shielding: Metal Shield (Stainless steel braided).
Check Stock

Inkbird PID Temperature Controller Kit High Voltage 100ACV to 240ACV Comes with SSR 40DA Solid State Relay K Type Thermocouple and White Heat Sink

  • 【Alarm Output】With one alarm relay output: AC250V 3A (Resistive load) ON/NC, you may connect it with a buzzer..
  • 【Supports 3 Wires Sensors】3 wires sensor or 2 wires sensor, like K type thermocouple and Cu500, are supported by this PID temperature controller.
  • 【SSR Output】With one relay output for external SSR, SSR or relay is a must for this temperature controller. A 40DA SSR is included.
  • 【Digital Display ℃/℉】It’s a digital PID controller but also supports Centigrade and Fahrenheit reading.
  • 【2 Temp Displaying Windows】The real-time temperature and the setpoint are shown at the same time.
Check Stock

Coolrunner Gas Patio Heater Repair Replacement Parts Outdoor Heaters Safety Kits Thermocouple (M8 x1) and FD4 Dump Switch for Propane Gas Patio Heater

  • Well Made & More Safe: The thermocouple is made of brass and red copper and the anti-tilt switch, made of ABS, which will automatically stop heating when the gas heater is tilted..
  • Wide Compatibility: The patio heater thermocouple replacement is suitable for most of propane heater, patio heater and other gas heaters with thermoelectric safety..
  • Dimension: The total length of thermocouple is 350mm, thermocouple probe is M6*0.75 and threaded end is M8*1, please measure your original parts before ordering. Weak current FD4 dump switch is for gas R≤10 mΩ..
  • Easy to install: It is easy to replace just follow the way you remove the defective part. Notice: Keep the thermocoupler probe about 5mm from the burner hole..
  • Great Value for Money: If the thermocouple or dump switch of your gas heater is broken, you just need to change the replacement that will save $200 for you..
Check Stock