Top Steel Din Rail

10Pcs DIN Rail Mounted Ground Circuit Connection Terminal Block Screw Clamp Connector (USLKG5N)

  • Type: USLKG2. 5N, Rated voltage/current: 690V/34A..
  • ✯ Material: Nylon PA66 Housing + Alloy Copper Bodies + Nickel-plated Screws..
  • ✯ Installation Method: DIN Rail Mounted, universal mounting foot to easily mount onto DIN rail..
  • ✯ Lock firmly on the din rail, easy to insert the wire and the screw terminal holds the wires solid. Great use when making a prewired harness..
  • ✯ Application: Distribution boxes/cabinets and other general terminals, such as: home appliances, electronic circuits, machines, etc..
Check Stock

Baomain DDS238-4 (30-100)Single Phase DIN-Rail Kilowatt Hour kwh Meter 220V 100A

  • Rate Voltage:220V 230V 240V Rate Current:30(100A).
  • 220V Single Phase DIN-rail Kilowatt Hour kwh Meter.
  • Insulation Performance:AC voltage 2KV for 1 minute,impulse voltage 6KV.
  • Accuracy Class:Class 1 Starting Current:0.4%lb.
  • 35mm standard DIN rail installation,complying with standard DIN EN5002.
Check Stock

StarTech.com 1 Port RS232 to Ethernet IP Converter / Device Server - Aluminum - Serial over IP Device Server - Serial to IP Converter (NETRS2321P)

  • ACCESS YOUR SERIAL DEVICES REMOTELY: Use this RS232 to Ethernet IP converter to connect to, configure and remotely manage an RS232 serial device over an IP network.
  • DURABLE CONSTRUCTION: Built with a rugged aluminum housing, this serial to IP Ethernet device server delivers a reliable performance that can be used in almost any environment.
  • FLEXIBLE INSTALLATION: This serial to IP converter can be mounted to a surface or on a DIN rail with the built-in mounting bracket and included DIN rail clips.
  • Access a serial device from anywhere with an IP-based connection.
  • Mount on DIN-rails or on a wall with the attached mounting brackets.
  • Suitable for hash environments with a rugged, aluminum enclosure.
  • Configure via web browser or Virtual Com software interface.
  • Support for DHCP, HTTP, ICMP, ARP, IP, UDP, TCP.
Check Stock

Electrodepot 40 Amp 4 Pole Normally Closed Contactor, 110-120V Coil, Motor Load 20A, Lighting 40A Bundle with Slotted Steel Zinc Plated DIN Rail, 35 mm x 6 in – 1 Piece with 2 Number 10 Screws

  • BUNDLE CONTENT: 4 ITEMS – One (1) 40A Contactor, one (1) compatible Slotted Steel Zinc Plated DIN Rail and two (2) drive stainless steel truss head screws (#10, 1/2") for immediate installation.
  • APPLICATIONS – Lighting, motor or switching. AC-1 for resistance furnaces, incandescent lamps or electric heaters.
  • and AC-3 for air conditioners, compressors or fans. 24/120/220/277 V, with an energy saving, silent and no humming coil.
  • COIL VOLTAGE AND LOAD – Contactor IEC 400V. Coil Voltage 110/120VAC, 50/60 Hz.
  • Coil load Inrush 30VA, Sealed 4VA. Inductive/Motor Load: 20Amp, Resistive/Incandescent Load: 40Amp. DC Load: 30Amp @ 24VDC. Compatible with 20 Amp, 30 Amp, 32 Amp and 40 Amp loads. Power Lug Terminal Capacity AWG # 4.
  • OTHER CONTACTOR DETAILS – Contactor type NC with 4 poles, power status indicator. IEC AC Rate: AC-1.
  • 8 kW. Electric e strength: 4 kV. Operating Temperature -30…+70 °C (-22…+158 °F). Dimensions (approx.): 85 x 45 x 92 mm / 3.4'' x 1.7'' x 3.6'' (Length x Width x Height).
  • DIN RAIL – Standard mounting support for any electromechanical component, including contactors, using the DIN specifications adopted by European (EN) and international (IEC) standards. Standard width 34.9mm (1.375”) length 152.40mm (6”) and t....
Check Stock

50 Amp 4 Pole Contactor Normally Open (N/O) 120V Coil, 32A Motor, IEC 63A, 60A DIN

  • Normally Open (N.O.) main contacts Power status indicator.
  • 110/120VAC Coil: 52VA inrush, 10VA sealed.
  • Overall Size(Approx.) : 60 x 55 x 67mm / 2.4" x 2.2" x 2.7"(L*W*T).
  • DIN rail included, Compliance: CE, and IEC/EN61095 DIN.
Check Stock

Electrodepot 40 Amp 12 Pole (4 Pole x 3) Normally Open, 110-120VAC Coil (Silent Operation), Motor Load 40A and Lighting Load 63A Contactor Bundle with 8\ DIN Rail and 2 Number 10 Screws

  • BUNDLE CONTENT: 6 ITEMS – Three (3) 40A 4 Pole Normally Open (NO) Contactors with power status indicator.
  • one (1) compatible Slotted Steel Zinc Plated 35mm x 200mm DIN Rail and two (2) stainless steel truss head screws (#10, 1/2") for immediate home or industrial installation.
  • CONTACTOR APPLICATIONS – Lighting, motor or switching. AC-1 for resistance furnaces, incandescent lamps or electric heaters.
  • and AC-3 for air conditioners, compressors or fans. 24/120/220/277 V, with an energy saving, silent and no humming coil.
  • COIL VOLTAGE AND LOAD – Contactor IEC 400V. Coil Voltage 110/120VAC, 50/60 Hz.
  • Coil load Inrush 52VA, Sealed 10VA. Inductive/Motor Load: 40Amp, Resistive/Incandescent Load: 63Amp. DC Load: 30Amp @ 24VDC. Compatible with 15 Amp, 20 Amp, 30 Amp, 32 Amp, 40 Amp, 50 Amp, 60 Amp and 63 Amp loads. Power Lug Terminal Capacity AWG # 4.
  • OTHER CONTACTOR DETAILS – Contactor type NO with 4 poles, power status indicator. IEC AC Rate: AC-1.
  • 8 kW. Electric e strength: 4 kV. Operating Temperature -30…+70 °C (-22…+158 °F). Dimensions (approx.): 54 x 64 x 84 mm / 2.1'' x 2.5'' x 3.3'' (Length x Width x Height).
  • DIN RAIL – Standard mounting support for any electromechanical component, including contactors, using the DIN specificat....
Check Stock

CZH-Labs DIN Rail Mount 12V Passive 2 SPST-NO 30Amp Power Relay Module.

  • DIN Rail Mount Passive 2 Channel SPST-NO 30 Amp Power Relay Module..
  • High quality DIN rail mount carrier, can support width 35mm /32mm / 15mm rail..
Check Stock

Electrodepot 40 Amp 8 Pole (4 Pole x 2) Normally Open, 110/120VAC Coil (Silent Operation), Motor Load 40A and Lighting Load 63A Contactor Bundle with DIN Rail, 35 x 150 mm and 2#10 Screws

  • BUNDLE CONTENT: 5 ITEMS – Two (2) 40A 4 Pole Normally Open (NO) Contactors with power status indicator.
  • one (1) compatible Slotted Steel Zinc Plated 35mm x 150mm DIN Rail and two (2) stainless steel truss head screws (#10, 1/2") for immediate home or industrial installation.
  • CONTACTOR APPLICATIONS – Lighting, motor or switching. AC-1 for resistance furnaces, incandescent lamps or electric heaters.
  • and AC-3 for air conditioners, compressors or fans. 24/120/220/277 V, with an energy saving, silent and no humming coil.
  • COIL VOLTAGE AND LOAD – Contactor IEC 400V. Coil Voltage 110/120VAC, 50/60 Hz.
  • Coil load Inrush 52VA, Sealed 10VA. Inductive/Motor Load: 40Amp, Resistive/Incandescent Load: 63Amp. DC Load: 30Amp @ 24VDC. Compatible with 15 Amp, 20 Amp, 30 Amp, 32 Amp, 40 Amp, 50 Amp, 60 Amp and 63 Amp loads. Power Lug Terminal Capacity AWG # 4.
  • OTHER CONTACTOR DETAILS – Contactor type NO with 4 poles, power status indicator. IEC AC Rate: AC-1.
  • 8 kW. Electric e strength: 4 kV. Operating Temperature -30…+70 °C (-22…+158 °F). Dimensions (approx.): 54 x 64 x 84 mm / 2.1'' x 2.5'' x 3.3'' (Length x Width x Height).
  • DIN RAIL – Standard mounting support for any electromechanical component, including contactors, using the DIN specificatio....
Check Stock

120VAC Din Rail Mounted Motor Contactor (100-C09D10)

  • Rated for 9A. Used only with Rockwell 193-T1A System Overloads..
Check Stock

Rollon TEX45-1520 X-Rail 45, 1520mm Length

Check Stock

mxuteuk 2pcs HH52P AC 24V Coil 8 Pin 5A DPDT LED Indicator Electromagnetic Power Relay, with Base, with DIN Rail Slotted Aluminum

  • Product Name:Electromagnetic Power Relay.
  • Overall size(approx. ): 75 x 22 x 66mm/3" x 0. 8" x 2. 6"(L*w*h).
  • Package Content : 2 x Power Relay + 2 x Socket + 1 x Rail Slotted Aluminum + 2 x Screw.
Check Stock

Homeline Plug-on Circuit Breaker HOM2150BB Branch 150 AMP UL Approved

  • UL489 Listed for branch circuit protection.
  • C Curve Trip with Visual trip indicator for quick troubleshooting.
Check Stock