Top Thread Mounted Thermocouple

Meter Star CE/CSA Certification Propane LPG Gas Room Space Heater & Outdoor Patio Heater Replacement Parts Gas control Safety Valve

  • Low pressure 65mbar gas valve thermocouple end M8*1.
  • 7/16-20UNS thread on outlet & M10*1 On inlet side.
  • M8*1 female thread on pilot port for 4mm copper or alumium tube on pilot burner side.
  • Shaft for 8mm knob,CE/ CSA approved parts.
  • Suitable for Gas patio heater and Room Space heater.
Check Stock

Aupoko Universal Thermocouple Patio Heater Parts, 350 mm Outdoor Heater Replacement Parts M8 x 1 End Connection Nuts Thermocouple 0.4 Meters Length M6 x 0.75 Head Thread 4.8 mm/ 0.19'' Flat Terminal

  • APPLICATION: This 350 mm thermcouple is suitable for patio heater..
  • PREMIUM QUALITY: High standard solid copper and brass material, high temperature resistance protection sleeve..
  • EASY INSTALLATION: You only need less than 10s to open the valve and don't need special tools for it..
  • HIGH TEMPERATURE RESISTANCE: The patio heater thermcouple is high temperature resistance with protection sleeve..
  • SIZE: Universal thermocouple with M6x0.75 thread on head, M8 x 1 end connection nuts thermocouple, total extend length 350 mm, with 4.8 mm/ 0.19'' flat terminal..
Check Stock

Sunpak-22024 Pilot Assembly for Ng O, Aluminium

  • Suitable for Lpg propane gas heaters /ovens.
  • One flame pilot burner kit including copper tube.
  • Whole kit assembly Copper tube length: 200mm.
Check Stock

Heatilator & Heat-N-Glo Natural Gas Pilot Assembly 4021-736

  • Pilot tube, thermocouple, thermopile, and ignitor wire are about 24" long..
Check Stock

Empire Comfort Systems Heritage Cast Iron Matte Black Stove DVP20CC70FN - Natural Gas

  • Volatge: >20mV, Open valve time less than 10s.
  • Used for gas fireplace, fire pit, grill, Stove, catering cooker, patio heaters etc.
Check Stock

Thermco ACC310DLSDIG Laboratory Long Stem Digital Thermometer, 12\ Stem Length, -50 to 300°C Range, +/-1.0°C Accuracy

  • High Temperature K-type Thermocouple Thermometer Set with Stainless Steel Probe.
  • K-type thermocouple wire with Standard Accuracy: +/- 2.2 °C or +/- .75%.
  • 5 ft (155 cm) long thermocouple cable with braided stainless steel cover, mini thermocouple plug made from chromel / alumel.
  • Temperature measurement range: -328 to 932 °F (-200 to 500 °C), short term 1472 °F (800 °C).
  • Grounded K-type Thermocouple junction for fast measurements, 1x 9V battery included.
Check Stock

Instrukart Dry Block High Temperature Calibrator AI-DBC 650 for Calibration Labs Pharmaceutical divisions Thermal Plants divisions Along with Calibration Certificate

  • Accuracy: ±0.6°C, Bath Stability: ±0.5°C.
  • Measuring Functions: J Type Thermocouple, K Type Thermocouple, T Type Thermocouple, R Type Thermocouple, S Type Thermocouple, N Type Thermocouple, MA, MV, Volts, Ohms, RTD (Pt 100).
  • Temperature Steps: 50°C, 150°C, 300°C, 450°C, 600°C.
  • Switch Test: Continuity check with OPEN / CLOSE indication.
  • Transmitter Supply: 24V DC ± 10% (Loop Powered).
  • Power Supply: 230V AC ± 5% / 50Hz, 500 W for 350UTC.
  • Supply Scope: Instrument, Power Cable, Carrying Case, Test Lead(2 & 3 Wire), Insertion Tube, Insertion Tool,Spare Fuses: 6A x 2nos User Manual, Calibration Certificate.
Check Stock

3\ Outside Air Kit for Pellet Stoves with 3\ Air Intake Pipe Including Harman Stoves 3\ X 10'

  • QuadraFire Thermocouple 800, 1000, 1100i, 1200, 1200i Pellet Stoves 812-0210.
  • Top Quality Aftermarket Replacement Part.
  • The Thermocouple is the device that monitors the fire after start-up. Once it reaches temp the thermocouple allows the stove to start feeding on it's own in normal operation mode. If your stove goes out after the initial start-up cycle, more than likely the thermocouple needs to be replaced..
  • Designed Specifically for the above mentioned models.
Check Stock

Montague OVEN THERMOCOUPLE 48\ 1036-7

  • K-type thermocouple connector with real chromel alumel contacts.
  • Miniature or mini k-type connector dimensions.
  • Works with all k-type thermocouple wires and extension wires.
  • Set of 10 male mini thermocouple connector plugs.
  • Compatible with thermocouple plugs from other manufacturers.
Check Stock

MENSI 24\ Propane BBQ Grill, Firepit, Fireplace Heater Universal Gas Thermocoupler Sensor M8x1 Thread

  • The Universal Thermocouple Total Length 24".
  • Head thread size: M8*1, End Nut size to connect valve: M8*1.
  • Head Need to Be Keep Heated During Using ( If Stops working, Please adjust the Tip Location again).
  • Volatge: >20mV, Open valve time less than 10s.
  • Used for gas fireplace, fire pit, grill, Stove, catering cooker, patio heaters etc.
Check Stock

Cooper Atkins 35132 Aquatuff with Wrap&Stow Duraneed

  • Waterproof Thermocouple Thermometer - Precise digital thermocouple thermometer, delivers a true +/- 0.9 degrees Fahrenheit accuracy and probes can be replaced in the field without the need for recalibration.
  • Heavy Duty Probe Cable - Patented thermocouple thermometer probe cable that neatly wraps and stows around the instrument. Uses any K Type probe.
  • DuraNeedle Probes - Best used for dense meats. Also works well with soft foods and liquids. Probe is calibrated with instrument for Total System Accuracy.
  • Waterproof Digital Thermocouple - Large easy to read digital LCD display, auto shutoff after 10 minutes of non-use. IPX7 waterproof rated.
  • Cooper-Atkins Corporation - Headquartered in Middlefield, CT, Cooper-Atkins has been a leading manufacturer of quality time, temperature, and humidity instruments serving the Foodservice, HVAC and Healthcare markets since 1885.
Check Stock

Coolrunner Gas Patio Heater Repair Replacement Parts Outdoor Heaters Safety Kits Thermocouple (M8 x1) and FD4 Dump Switch for Propane Gas Patio Heater

  • Well Made & More Safe: The thermocouple is made of brass and red copper and the anti-tilt switch, made of ABS, which will automatically stop heating when the gas heater is tilted..
  • Wide Compatibility: The patio heater thermocouple replacement is suitable for most of propane heater, patio heater and other gas heaters with thermoelectric safety..
  • Dimension: The total length of thermocouple is 350mm, thermocouple probe is M6*0.75 and threaded end is M8*1, please measure your original parts before ordering. Weak current FD4 dump switch is for gas R≤10 mΩ..
  • Easy to install: It is easy to replace just follow the way you remove the defective part. Notice: Keep the thermocoupler probe about 5mm from the burner hole..
  • Great Value for Money: If the thermocouple or dump switch of your gas heater is broken, you just need to change the replacement that will save $200 for you..
Check Stock